Ls300 Barcode Scanner Manual

Ls300 Barcode Scanner Manual Average ratng: 3,3/5 9374 reviews

Barcode Scanner Magstripe Programming Manual Decoder & Scanner. Installing a RS-232 Interface Barcode Scanner. 3 Barcode Scanner Setup Procedures 1).

  1. Zebra Barcode Scanner Manual

. LS 3070 Product Reference Guide Click on red text at any location in the manual to jump to the specified chapter, topic, or reference. About This Manual Table of Contents Copyright Feedback Index 70-10294-02 Revision B February 1998. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products.

Symbol is a registered trademark of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. LS 3070 Standard Range. LS 3070 Standard Technical Specifications. Code Types.6-3 Code Lengths.

UPC-A Preamble.7-37 UPC-E Preamble. About This Manual The LS 3070 Product Reference Guide provides general instructions for setup, operation, troubleshooting, maintenance, and programming.

Notational Conventions The following conventions are used in this document: Bullets (.) indicate:. action items - lists of alternatives - lists of required steps that are not necessarily sequential Sequential lists (e.g., those that describe step-by-step procedures) appear.

LS 3070 Product Reference Guide: About This Manual Note: Symbol Technologies is not responsible for any damages incurred dur- ing shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping con- tainer was not kept, contact Symbol to have another sent to you. The LS 3070 is a revolutionary, cordless approach to capturing bar coded data. The scanner communicates with your host computer through a low-power radio transmission instead of through a cable.

With the LS 3070, you are free to scan and transmit without a physical cable to limit your movement, from as far away as 30 - 50 feet (9 - 15 meters), depending on your environment. LS 3070 Product Reference Guide: The LS 3070 Cordless Scanner The LS 3070 Scanner Housed in rugged, durable plastic, the LS 3070 scanner combines accurate, aggressive bar code scanning with solid state dependability. Its ergonomic design ensures comfortable use for extended periods of time. 8-hour shift. When fully depleted, the battery module can be recharged to full charge within two hours, with the LS 3070 inserted into the RL 470 base/charger unit. Alternatively, the battery module can be recharged in the Universal Four-Slot Charger/Recharger within 8 hours. LS 3070 Product Reference Guide: The LS 3070 Cordless Scanner The Base/Charger Unit The base/charger unit has two primary functions.

First, it is the base station interface that manages the flow of information from the scanner to the host device. Second, it is a charging stand which charges the scanner’s battery module (located in the handle) and also holds the scanner securely when it is not in use. Setup Unpacking Remove the LS 3070, the RL 470 base/charger unit, and the host interface cable from its packing and inspect each for evidence of physical damage. If any equipment was damaged in transit, call the Symbol Support Center at the number in the front matter. Proper base positioning gives you the best possible range and coverage performance from the LS 3070 cordless scanning system. Inserting the Scanner Into and Removing Scanner from Base/Charger To insert the scanner into the base/charger: 1.

LS 3070 Product Reference Guide: Setup Charging the Battery Before its first use, the LS 3070 batteries must be charged. To do so: Connect the power supply to the power input port on the front panel of. the RL 470 base/charger, shown in page 1-4. LS 3070 Product Reference Guide: Setup Note: When setting the address of the base, you automatically set the initial frequency on which the base and the scanner communicate. In order to minimize possible interference between systems, bases which are close to each other should be assigned sequential addresses. LS 3070 Product Reference Guide: Setup Possible Base/Charger Addresses 01 02 03 04 05 10 11 12 13 14 15 20 21 22 23 24 25 30 31 32 33 34 35 40 41 42 43 44 45 50 51 52 53 54 55. (Note that data is transmitted between a scanner and base so quickly that a number of different LS 3070 systems can normally operate on the same channel without noticeable interference.).

find a particular scanner/base pair has trouble communicating over a normal operating distance, try setting different transmission frequencies to see if performance improves. (The LS 3070 system changes channels automatically if it encounters interference as much as 80% of the time over a continuous 5- minute period.). Chapter 3 Scanning with the LS 3070 1. Ready Before starting to scan bar codes for data collection, make sure: The base station is connected to the host device.

The battery has been charged. The scanner is paired with the base/charger. LS 3070 Product Reference Guide: Scanning with the LS 3070 If the scanning attempt ends in 4 error beeps, any of these may be true: Scanner is out of transmission range. Scanner and base/charger are not paired. Base/charger is not powered. LS 3070 Product Reference Guide: Scanning with the LS 3070 Using a Long Range or High Visibility Scanner? These scanners have two-position triggers.

Press the trigger to the first detent and center the “collapsed” aiming beam on the target bar code, as illustrated below. LS 3070 Product Reference Guide: Scanning with the LS 3070 Scanning Transmission Range RF Communication Errors RF communication errors occur when the scanner is out of range from the base during a scan data transmission attempt. An error is indicated by 6 beeps after a bar code is scanned, although the bar code data appears on the host display.

LS 3070 Product Reference Guide: Scanning with the LS 3070 What If. Nothing happens when you follow the operating instructions? You should Check that the power supply is attached to the base/charger.

Check for loose cable connections at the base/charger and host device. LS 3070 Product Reference Guide: Scanning with the LS 3070 Decode Zones LS 3070 Standard Range NOTE: Typical performance at 23 Front of the Scanner.0055 In.0075 In.020 In. Minimum Element Width.040 In.

Minimum Element Width 12.7 Depth of field as a function of minimum element width. LS 3070 Product Reference Guide: Scanning with the LS 3070 LS 3070LR Long Range NOTE: Typical performance at 23 Front of the Scanner 7.5 Mil 10 Mil 15 Mil 20 Mil 40 Mil Depth of field as a function of minimum element width. LS 3070 Product Reference Guide: Scanning with the LS 3070 LS 3070ALR Advanced Long Range NOTE: Typical performance at 23 Front of the Scanner 15 Mil 40 Mil Figure 3-3. LS 3070ALR Decode Zone: Depth of field as a function of minimum element width.

LS 3070 Product Reference Guide: Scanning with the LS 3070 LS 3070XLR Extra Long Range NOTE: Typical performance at 23 Front of the Scanner Figure 3-4. LS 3070XLR Decode Zone: Depth of field as a function of minimum element width. LS 3070 Product Reference Guide: Scanning with the LS 3070 LS 3070HV High Visibility NOTE: Typical performance at 23 Front of the Scanner.0075 In.020 In.

Minimum Element Width 12.7 Figure 3-5. LS 3070HV Decode Zone: Depth of field as a function of minimum element width. Chapter 4 Maintenance and Specifications Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. Do not allow any abrasive material to touch the window.

Remove any dirt particles with a damp cloth. LS 3070 Product Reference Guide: Maintenance and Specifications Power Supply Connection Port Figure 4-1. Recharging the LS 3070 Changing Battery Packs You can charge battery packs on the Universal Four Slot Battery Charger so that a charged battery pack is available when needed. In this case, simply remove the depleted battery pack and replace it with a freshly charged one. LS 3070 Product Reference Guide: Maintenance and Specifications 1. Remove Lower Handle from Scanner.

Using a probe, press in the release button on the handle, as indicated at the right. With button pressed in below the outer housing, slide the battery pack out from the handle. LS 3070 Product Reference Guide: Maintenance and Specifications Charge Status LED Indications On the base/charger, there is a red LED indicator which uses flashing patterns to indicate the current charger status. The red Charge Status LED indicates the following conditions: RED LED OFF —.

LS 3070 Product Reference Guide: Maintenance and Specifications Accessories Standard Accessories Part Number RL 470 Base/Charger Cable: 70-10294-8-4-01Q 50-04000-00-00-037 Optional Accessories Optional accessories, listed in the Electronic Product Ordering Guide, include various rechargers, magstripe readers, stands, and holders, which are supplied at extra cost. LS 3070 Product Reference Guide: Maintenance and Specifications LS 3070 Standard Technical Specifications ITEM Power Requirements: Scanner Base/Charger Scan Repetition Rate Start-up Time Data Acquisition Time Skew Tolerance Pitch Angle Decode Depth of Field Minimum Element Width Maximum Element Width. LS 3070 Product Reference Guide: Maintenance and Specifications LS 3070LR Technical Specifications ITEM Power Requirements: Scanner Base/Charger Scan Repetition Rate Start-up Time Data Acquisition Time Skew Tolerance Pitch Angle Decode Depth of Field Minimum Element Width Maximum Element Width Print Contrast Minimum. LS 3070 Product Reference Guide: Maintenance and Specifications LS 3070ALR Technical Specifications ITEM Power Requirements: Scanner Base/Charger Scan Repetition Rate Start-up Time Data Acquisition Time Skew Tolerance Pitch Angle Decode Depth of Field Minimum Element Width Maximum Element Width Print Contrast Minimum. LS 3070 Product Reference Guide: Maintenance and Specifications LS 3070XLR Technical Specifications ITEM Power Requirements: Scanner Base/Charger Scan Repetition Rate Start-up Time Data Acquisition Time Skew Tolerance Pitch Angle Decode Depth of Field Minimum Element Width Maximum Element Width Print Contrast Minimum. LS 3070 Product Reference Guide: Maintenance and Specifications LS 3070HV Technical Specifications ITEM Power Requirements: Scanner Base/Charger Scan Repetition Rate Start-up Time Data Acquisition Time Skew Tolerance Pitch Angle Decode Depth of Field Minimum Element Width Maximum Element Width Print Contrast Minimum. Interface Guide Connecting to a Host Device In most cases, connecting your LS 3070’s base station to your host terminal is a very simple operation.

You need only plug the cable into your host. Typical configurations are shown on the following pages. Some POS keyboards require more intricate installation instructions. LS 3070 Product Reference Guide: Interface Guide Connecting Base Station to a Host OCIA and OCR Terminals The OCIA or OCR port must be activated and referenced by the POS system, or no communications will take place. POS Terminal Base Station Figure 5-1. LS 3070 Product Reference Guide: Interface Guide RS-232C Single Port RS-232C Device Base Station Figure 5-2.

Connecting Base Station to RS-232C Single-Port Host Any of the following RS-232C (DB 25) connectors are supported: Male, TxD on pin 2 or TxD on pin 3. Female, TxD on Pin 2 or Pin 3. For other pinouts and cable types, contact the Symbol Support Center at 1-800-653-5350. LS 3070 Product Reference Guide: Interface Guide IBM 4683/4684/4693/4694 IBM 4683/4 IBM 4693 IBM 4694 Figure 5-4. Connecting Base Station to IBM 4683/4684/4693/4694 To connect the base station, plug the cable into the appropriate port on the rear of the IBM 4683/84, 4693/94.

LS 3070 Product Reference Guide: Interface Guide Connecting Keyboard Wedges Terminal Base Station Keyboard Figure 5-5. Connecting Base Station to Keyboard Wedge These include: PC Keyboards IBM PC/AT/XT, PS2-30/50/55SX/60/70 and clones. Terminal Keyboards DEC VT2XX/VT3XX/4XX; HP 700/92, 2392; IBM 3178/3278/3151/316X/ 3179/3180/319X, 3278, 347X.

LS 3070 Product Reference Guide: Interface Guide IBM 3683/3684 Installation Install cables as described below. Failure to do so may re- sult in hardware damage. There are four basic steps to this installation: 1. Remove the IBM 3683/84 top cover.

LS 3070 Product Reference Guide: Interface Guide Third: Install the Cable Internally The base station cable is installed internal to the IBM 3683/84 with the cable exiting the rear of the terminal. Remove the printer assembly as follows: Disconnect the printer ground strap (slide on connector) from the right. LS 3070 Product Reference Guide: Interface Guide Fourth: Replace the Keyboard and Top Cover 1. Replace the keyboard down into the retaining glides. Replace the top cover as follows: Replace the display cable if display is integrated. Hold the cover so that rear slots fit into retaining tabs. LS 3070 Product Reference Guide: Interface Guide Connector Printer Ground Strap Figure 5-7.

Disconnecting Cable from Connector Locking Tab Figure 5-8. Sliding Printer Locking Tabs.

LS 3070 Product Reference Guide: Interface Guide Figure 5-9. Cable Figure 5-10. J16 Connector 5-10. LS 3070 Product Reference Guide: Interface Guide Figure 5-11.

Connecting J2 to J16 Figure 5-12. Securing J1 5-11. LS 3070 Product Reference Guide: Interface Guide IBM 3653 Installation 1. Be sure the IBM 3653 terminal is powered-down. Open the door over the ribbon cartridge as shown in 2.

Loosen the right side panel screw (see at top of the rear corner; pull out to the side and push back to remove the panel. LS 3070 Product Reference Guide: Interface Guide 11. Remove the protective foam from the register end of the base station Y- cable, and insert into the cable assembly. Place the assembly near the bottom of the register behind the keyboard. LS 3070 Product Reference Guide: Interface Guide Screws Figure 5-14. Removing Keyboard Cover Figure 5-15. Sliding Base Station Cable Through Hole 5-14.

LS 3070 Product Reference Guide: Interface Guide Figure 5-16. Opening Card Cage Figure 5-17. Connecting Probes 5-15.

LS 3070 Product Reference Guide: Interface Guide Figure 5-18. Voltage Adjustment Hole Figure 5-19. Installing Keyboard Connector 5-16. LS 3070 Product Reference Guide: Interface Guide NCR 280 Installation 1. Ensure that the NCR 280 is powered down and unplugged.

Open the door on the top, left-hand side and remove the two screws which fasten the steel plate to the terminal cover. Slide the steel plate to the left to remove.

LS 3070 Product Reference Guide: Interface Guide 12. Diameter semicircle at the bottom left of the terminal cover, approximately 6 1/2 in. From the back of the unit, so that when the cover is replaced, this opening fits over the cable. Be sure to file down all sharp edges. LS 3070 Product Reference Guide: Interface Guide 5.

Locate the end of the RL 470 base station cable that branches into a “Y”. Slide that end under the board assembly inside the register. Leave enough slack to make the connection required in the next few steps. LS 3070 Product Reference Guide: Interface Guide NCR 2152 Installation 1. Switch off the NCR 2152. Remove the two large, pan head screws from the front of the terminal to allow the top section to open up.

Use the two hood support rods located to the sides of the housing to support the top section. LS 3070 Product Reference Guide: Interface Guide NCR 2154/2155 Installation 1. Power-down the NCR 2154/2155 POS terminal. Remove the keyboard by grasping the keyboard cover at its corners and lifting upward.

Remove the cable connecting the keyboard to the terminal’s main PC board. LS 3070 Product Reference Guide: Interface Guide Fujitsu 9000 Installation 1. Switch-off the Fujitsu 9000, and disconnect the power. Push down on the keyboard release latch below the keyboard.

Manual

Pull the keyboard forward, lift and remove 2. Press down the printer release tab. Push the printer back and remove. Press down the display release tab. LS 3070 Product Reference Guide: Interface Guide Interfaces Select the appropriate interface cable assembly for your host system. Host DEC VT 2XX/3XX/4XX Fujitsu 7770, 7880, 7990, 8770 Fujitsu 9000 Fujitsu 9000 HP 700/XX, 239X RS-232C TxD on Pin 2, Male.

LS 3070 Product Reference Guide: Interface Guide Host NCR 280 NCR 2126-1120 NCR 2151 NCR 2152 NCR 2152/2257/2950 NCR 2154/2155/2157/7050 NCR 7052 NCR 7052 Nixdorf 8812 Telex Memorex 88, 122 Wyse 60, 85, 150, 150+, 185 Type Interface P/N Wedge. Chapter 6 Programming Programming Overview Before programming, follow the instructions in the 5: Interface Guide. Programming occurs through use of bar code menus.

Zebra Barcode Scanner Manual

Not all parameters, however, apply to your specific host. For example, if you have an OCIA terminal, RS-232C parameters such as baud rate and parity will not apply. Simply ignore those parameters not designed for your application. LS 3070 Product Reference Guide: Programming Scanning Sequence Examples In most cases you need only scan one bar code to set a specific parameter. For example, if you want to set the baud rate to 9600, simply scan the 9600 bar code listed under Baud Rate. LS 3070 Product Reference Guide: Programming Parameter Descriptions Set Parameter Defaults Scanning the SET DEFAULT bar code returns all parameters to the values listed in the Default Table beginning on page Host Interface Code Each Interface Cable Assembly defaults to a given host. These assemblies, their corresponding defaults, and additional bar codes begin in Menus.

Code 39 Full ASCII is enabled and a +B is scanned, it will be interpreted as b,%J as?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M will output the keystroke equivalent of ABC ENTER. The LS 3070 will not autodiscriminate between Code 39 and Code 39 Full ASCII. EAN plus supplemental symbol, the UPC/EAN will be decoded and the supplemental characters ignored. If autodiscrimination is chosen, the LS 3070 will, after additional processing to ensure a good decode, transmit either.

Ls300 Barcode Scanner Manual

(NOTE: To minimize the risk of invalid data transmission, it is recommended that you select whether to read. LS 3070 Product Reference Guide: Programming Code 39 Check Digit When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with a modulo 43 check digit algorithm. ITF-14/EAN-13 Conversion If your terminal supports EAN-13, this feature converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. Beeper Definitions beginning on page UPC/EAN Security Level The LS 3070 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality.

There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application. LS 3070 Product Reference Guide: Programming Decode Redundancy Use this parameter to indicate whether the scanner must read a bar code one time (LEVEL 1), two times (LEVEL 2), or three times (LEVEL 3) before decoding it.

A higher level of redundancy ensures the accuracy of a decode in, for example, poor quality symbols. LS 3070 Product Reference Guide: Programming Data Transmission Formats Magstripe Data Transmission Format Magstripe data format options are open for user determination with the specific application. The following are standard selections: Standard:. Option 1. LS 3070 Product Reference Guide: Programming Scan Data Transmission Format Scan data format options can be selected by the user.

The following are standard selections: Standard:. Option 1:. Option 2:.

LS 3070 Product Reference Guide: Programming RS-232C Options Baud Rate Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form. LS 3070 Product Reference Guide: Programming When the CTS line is negated, the base asserts the RTS line and waits for. one second for the host to assert CTS. When the host asserts CTS, data is transmitted. When data transmission is complete, the base will negate RTS 10 msec.

LS 3070 Product Reference Guide: Programming Software Handshaking This parameter offers control of the data transmission process. It may be used instead of, but not in conjunction with, hardware handshaking. The base station also provides four software handshaking options: NONE, ENQ, ACK/ NAK, and ACK/NAK with ENQ. LS 3070 Product Reference Guide: Programming When you select the wait for ENQ option, the base station waits for an ENQ, Enquire character, from the host before it transmits data; otherwise the unit transmits data without waiting for an ENQ character from the host. LS 3070 Product Reference Guide: Programming Serial Response Timeout This parameter determines the maximum period allowed to elapse before the base station assumes end of transmission. The delay period can range from 0 to 9.9 seconds. Stop Bit Select The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream.

LS 3070 Product Reference Guide: Programming Intercharacter Delay Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 msec delay between the transmission of each character. LS 3070 Product Reference Guide: Programming OCIA Transmit Timeout When connected to an OCIA terminal, the RL 470 base/interface will attempt to transmit the data to the host.

If the host is not prepared to accept data at that time (i.e., the host data buffer may be full), the RL 470 will try to retransmit the data for up to 3 seconds. LS 3070 Product Reference Guide: Programming National Keyboard Types Use this parameter to set the national character type for keyboard characters. Selections include U.S. English, French, German, French International, Spanish, Italian, Swedish, and U.K. The following terminals do not support Italian or French International but do support the other six options: IBM 3680, 316X, 319X. LS 3070 Product Reference Guide: Programming Table 6-1. Hosts Supported by Industrial Scanners Host Interface U.S.

PC AT PC XT PS/2 Single RS-232 Dual RS-232 Dec VT 220 Dec VT 320 Dec VT 420 HP 700/9XX IBM 316X IBM 319X. LS 3070 Product Reference Guide: Programming Set Transmission Frequency Use this parameter to set an initial transmission frequency to avoid interference on the default channel (channel 50). During operation, the transmission channel changes automatically whenever interference is encountered 80% of the time or more over a continuous five-minute period. LS 3070 Product Reference Guide: Programming Parameter Selections Supported features for each host type. Decode Parameters Add Codes to be Decoded ASCII Format Baud Rate Beep After Good Decode Beeper Volume Check Parity Codabar Any Length Codabar Length W/I Range. LS 3070 Product Reference Guide: Programming Decode Parameters Decode Redundancy EAN Zero Extend Hardware Handshaking Host Interface Code IBM 468X/9X Mgstrpe Comm.

Ignore Unknown Chars. Intercharacter Delay I 2 of 5 Any Length I 2 of 5 Length Within Range. LS 3070 Product Reference Guide: Programming Decode Parameters Scan Suffix Serial Response Time-out Software Handshaking Transmit AIM Code ID Transmit Code ID Chars. Transmit MSI Check Digit Transmit No Decode Message Transmit UPC-A Check Digit Transmit UPC-E Check Digit UPC/EAN Security Level. LS 3070 Product Reference Guide: Programming Beeper Definitions Standard Use Beeper Sequence 1 Beep - short high tone 2 Beeps - long high tone 4 Beeps - long high tone 5 Beeps - long high tone 6 Beeps - short low tone. LS 3070 Product Reference Guide: Programming Parameter Menu Scanning Beeper Sequence 1 Beep - short high tone 1 Beep - lo/hi tone 1 Beep - hi/lo tone 1 Beep - hi/lo/hi/lo tone Code 39 Scan And Store Beeper Sequence 1 Beep - hi/lo tone. LS 3070 Product Reference Guide: Programming Code 39 Buffering While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed.

To allow disabling of Code 39 buffering, first force the buffer transmission (see. LS 3070 Product Reference Guide: Programming Transmit Buffer To transmit the buffer, read a symbol containing either the first or second condition: 1. Only a start character, a plus (+), and a stop character. The unit signals that the transmission buffer has been sent (a hi/lo beep). LS 3070 Product Reference Guide: Programming Default Table Host Interface Code Types Code Lengths: Code 39 Code 128 Codabar I 2 of 5 D 2 of 5 MSI Plessey Decode Options Transmit UPC-A Check Digit Transmit UPC-E Check Digit Convert UPC-E to UPC-A. LS 3070 Product Reference Guide: Programming Scan Data Transmission Format Laser Control: Laser On Time-out RS-232C Options Baud Rate Parity Check Parity Hardware Handshaking Software Handshaking Serial Response Time-out Stop Bit Select ASCII Data Format RTS Line State Intercharacter Delay.

LS 3070 Product Reference Guide: Programming. Prefix/Suffix values only apply when the selected transmission format uses them. For example, if you select the default setting for Scan Data Transmission Format (Data As Is), any prefix or suffix selected is not recognized, since the format requires neither. LS 3070 Product Reference Guide: Programming Terminal Specific RS-232C Defaults Two RS-232C hosts are set up with their own parameter default settings. Selecting the ICL or Nixdorf RS-232C terminal will set the defaults listed below. These defaults take precedence over standard defaults.

So, if you’ve selected Nixdorf RS-232C, then select the standard defaults, the Nixdorf defaults will still take precedence. LS 3070 Product Reference Guide: Programming Table 6-4. Terminal-Specific RS-232 Defaults Parameter RS-232C Code 128 Code ID RS-232C I 2 of 5 Code ID RS-232C MSI/Plessey Code ID Standard “D” None “F” “I” “J” None 6-32 NIXDORF “K” “I” “O”. Chapter 7 Parameter Menus While the last section provided descriptions of all parameter options and other programming information, this one provides the bar codes to do the actual programming. LS 3070 Product Reference Guide: Programming Set Default Parameter Defaults are those listed in the Default Table beginning on page 6-28.

SET DEFAULTS SET ICL RS-232C DEFAULTS SET NIXDORF RS-232C DEFAULTS. LS 3070 Product Reference Guide: Programming Host Interface To select a host interface: 1.

Locate the type of interface from the list below. Scan the corresponding bar code from those on the following pages. Host Interface RS-232C RS-232 Single Port. LS 3070 Product Reference Guide: Programming Note: In some cases, two bar codes may correspond to one interface type; this happens when different software revisions exist for the same host type. If there are two bar codes for your host type, try the first bar code; if that does not work, then try the second one. LS 3070 Product Reference Guide: Programming Four Options for Dual Port RS-232: Dual Port RS-232: Transmit and Receive from Port 1. Dual Port RS-232: Transmit to Ports 1 and 2 — Receive from Port 1.

Dual Port RS-232: Transmit and Receive from Port 2. LS 3070 Product Reference Guide: Programming IBM PC/AT, IBM PS2-50/55SX/60/70/80 and Clones IBM PC/XT And Clones IBM PS2-30 and Clones IBM 3653 Keyboard Wedge. LS 3070 Product Reference Guide: Programming IBM 3683/3684 Calc 35 Keyboard Wedge IBM 3683/3684 Calc 48 Keyboard Wedge IBM 3683/3684 Calc 116 Keyboard Wedge. LS 3070 Product Reference Guide: Programming IBM 3683/3684 Tel 35 Keyboard Wedge IBM 3683/3684 Tel 48 Keyboard Wedge IBM 3683/3684 Tel 116 Keyboard Wedge. LS 3070 Product Reference Guide: Programming NCR 2151 (Tel) Keyboard Wedge NCR 2151 (Calc) Keyboard Wedge NCR 2152 (Tel) Keyboard Wedge NCR 2152 (Calc) Keyboard Wedge.

LS 3070 Product Reference Guide: Programming NCR 280 Keyboard Wedge NCR 255/2152/2154/2155, NCR 2126-1120 NCR 2157/2257/7050, NCR “S” 7052 OCIA NCR 7052 Keyboard Wedge NCR “F” 7052 OCIA 7-10. LS 3070 Product Reference Guide: Programming NCR “S” 2950 OCIA Nixdorf 8812 OCIA ICL 9505/9507/9518/9520 OCIA Spectra Physics OCIA 7-11. LS 3070 Product Reference Guide: Programming IBM 4683/4684 Port 5B 4693 IBM 4683/4684 Port 9B 4693 IBM 4683/4684 Port 17 IBM 3653/3683/3684 OCR 7-12.

LS 3070 Product Reference Guide: Programming Fujitsu 7770/7880/7990/ 8770/9000 OCR HP 239X HP 700-9X DEC VT 220/320 DEC VT 420 7-13. LS 3070 Product Reference Guide: Programming IBM 3178 IBM 3278 IBM 319X/347X/348X, Telex Memorex 122 IBM 3151/316X IBM 3179/3180 7-14. LS 3070 Product Reference Guide: Programming IBM 3180 (Later Software Revision) — See Note, p.

Telex Memorex 88 Telex 122 (Variant ENTER Key from that on Telex Memorex 122) Wyse 50 (ASCII Keybd) Wyse 60 (ASCII Keybd) Wyse 150 / Wyse 150+. LS 3070 Product Reference Guide: Programming Wyse 60 (PC Keybd) Wyse 150 / Wyse 150+ Wyse 60/150 (ANSI 101 Keybd) Wyse 85/150+/185 (ANSI 105 Keybd) HP 2392 (Later Software Revision) — See Note, p. LS 3070 Product Reference Guide: Programming Code Type Add or delete specific code types by scanning the appropriate bar code(s).

ENABLE ALL CODE TYPES DISABLE ALL CODE TYPES 7-17. LS 3070 Product Reference Guide: Programming ADD CODE 39 DELETE CODE 39 ADD CODE 39 FULL ASCII. DELETE CODE 39 FULL ASCII. ADD UPC/EAN.Adding or deleting Code 39 Full ASCII only has an effect when Code 39 has been selected. LS 3070 Product Reference Guide: Programming DELETE UPC/EAN ADD CODE 128 DELETE CODE 128 ADD EAN 128 DELETE EAN 128 7-19. LS 3070 Product Reference Guide: Programming ADD D 2 of 5 DELETE D 2 of 5 ADD I 2 of 5 DELETE I 2 of 5 7-20. LS 3070 Product Reference Guide: Programming ADD CODABAR DELETE CODABAR ADD MSI Plessey DELETE MSI Plessey 7-21.

LS 3070 Product Reference Guide: Programming Code Lengths To select two lengths for each code type: 1. Scan the desired option.

Scan two bar codes on example, for a length of “12”, scan “1” then “2”. For a length of “3”, scan “0”, then “3”. LS 3070 Product Reference Guide: Programming CODE 128 - ANY LENGTH CODABAR - ANY LENGTH CODABAR - LENGTH WITHIN RANGE CODABAR 1 - DISCRETE LENGTH CODABAR - 2 DISCRETE LENGTHS 7-23. LS 3070 Product Reference Guide: Programming I 2 OF 5 - ANY LENGTH.

I 2 OF 5 - LENGTH WITHIN RANGE I 2 OF 5 - 1 DISCRETE LENGTH I 2 OF 5 - 2 DISCRETE LENGTHS. Choosing I 2 of 5 Any Length may lead to misreads for I 2 of 5 and UPC codes. LS 3070 Product Reference Guide: Programming D 2 OF 5 - ANY LENGTH D 2 OF 5 - LENGTH WITHIN RANGE D 2 OF 5 - 1 DISCRETE LENGTH D 2 OF 5 - 2 DISCRETE LENGTHS 7-25. LS 3070 Product Reference Guide: Programming MSI Plessey - ANY LENGTH MSI Plessey - LENGTH WITHIN RANGE MSI Plessey - 1 DISCRETE LENGTH MSI Plessey - 2 DISCRETE LENGTHS 7-26. LS 3070 Product Reference Guide: Programming 7-27. LS 3070 Product Reference Guide: Programming CANCEL 7-28. LS 3070 Product Reference Guide: Programming Decode Options Enable or disable a specific decode option by scanning the appropriate bar code.

TRANSMIT UPC-A CHECK DIGIT DO NOT TRANSMIT UPC-A CHECK DIGIT TRANSMIT UPC-E CHECK DIGIT DO NOT TRANSMIT UPC-E CHECK DIGIT. LS 3070 Product Reference Guide: Programming ENABLE 1 MSI Plessey CHECK DIGIT ENABLE 2 MSI Plessey CHECK DIGITS CONVERT UPC-E TO UPC-A DO NOT CONVERT UPC-E TO UPC-A 7-30. LS 3070 Product Reference Guide: Programming DECODE UPC/EAN SUPPLEMENTALS IGNORE UPC/EAN SUPPLEMENTALS AUTODISCRIMINATE UPC/EAN SUPPLEMEN- ENABLE EAN ZERO EXTEND DISABLE EAN ZERO EXTEND 7-31. LS 3070 Product Reference Guide: Programming TRANSMIT “NO DECODED MESSAGE DO NOT TRANSMIT “NO DECODE” MESSAGE ITF14/EAN-13 CONVERSION ENABLED ITF14/EAN-13 CONVERSION DISABLED 7-32. LS 3070 Product Reference Guide: Programming BUFFER CODE 39 DO NOT BUFFER CODE 39 VERIFY CODE 39 CHECK DIGIT DO NOT VERIFY CODE 39 CHECK DIGIT 7-33.

LS 3070 Product Reference Guide: Programming BI-DIRECTIONAL REDUNDANCY ENABLED BI-DIRECITONAL REDUNDANCY DISABLED BEEP AFTER GOOD DECODE DO NOT BEEP AFTER GOOD DECODE 7-34. LS 3070 Product Reference Guide: Programming LOW BEEPER VOLUME HIGH BEEPER VOLUME UPC/EAN SECURITY LEVEL 0 UPC/EAN SECURITY LEVEL 1 UPC/EAN SECURITY LEVEL 2 7-35. LS 3070 Product Reference Guide: Programming UPC/EAN SECURITY LEVEL 3 DECODE REDUNDANCY 1 DECODE REDUNDANCY 2 DECODE REDUNDANCY 3 7-36. LS 3070 Product Reference Guide: Programming UPC-A Preamble Select one option for UPC-A preamble by scanning the appropriate bar code. NONE SYSTEM CHARACTER SYSTEM CHARACTER & COUNTRY CODE 7-37. LS 3070 Product Reference Guide: Programming UPC-E Preamble Select one option for UPC-E preamble by scanning the appropriate bar code. NONE SYSTEM CHARACTER SYSTEM CHARACTER & COUNTRY CODE 7-38.

LS 3070 Product Reference Guide: Programming Pause Duration To set a pause duration: 1. Scan the PAUSE DURATION bar code below. Scan two bar codes on the next two pages which represent the desired pause. You must always scan two bar codes. LS 3070 Product Reference Guide: Programming 7-40. LS 3070 Product Reference Guide: Programming CANCEL 7-41.

LS 3070 Product Reference Guide: Programming Prefix/Suffix Values Note: These values will also be used for Advanced Data Formatting programming. See the Advanced Programmer’s Guide for details. To set a PREFIX/SUFFIX value: 1. Scan the option bar code you wish to set. LS 3070 Product Reference Guide: Programming SCAN SUFFIX (VALUE 1) SCAN PREFIX (VALUE 2) MAGSTRIPE SUFFIX (VALUE 3) MAGSTRIPE PREFIX (VALUE 4) 7-43.

LS 3070 Product Reference Guide: Programming 7-44. LS 3070 Product Reference Guide: Programming CANCEL 7-45. LS 3070 Product Reference Guide: Programming Data Transmission Formats To select a data transmission format: 1. Scan the SCAN OPTIONS or MAGSTRIPE OPTIONS bar code.

Scan the bar code corresponding to the desired converted data format. LS 3070 Product Reference Guide: Programming ENTER 7-47. LS 3070 Product Reference Guide: Programming Magstripe Options MAGSTRIPE OPTIONS DATA AS ON CARD 7-48. LS 3070 Product Reference Guide: Programming 7-49. LS 3070 Product Reference Guide: Programming 7-50. LS 3070 Product Reference Guide: Programming 7-51. LS 3070 Product Reference Guide: Programming ERASE ALL FORMATS ERASE LAST ENTERED FORMAT CANCEL ENTER 7-52.

LS 3070 Product Reference Guide: Programming Laser Control To select a laser-on timeout: 1. Scan the LASER ON TIMEOUT bar code below. Scan two bar codes from the next two pages which correspond to the desired time. If you make an error, or wish to change your selection, scan CANCEL. LS 3070 Product Reference Guide: Programming 7-54. LS 3070 Product Reference Guide: Programming CANCEL 7-55. LS 3070 Product Reference Guide: Programming Baud Rate Set the baud rate for RS-232C transmission.

LS 3070 Product Reference Guide: Programming 2400 4800 9600 19200 7-57. LS 3070 Product Reference Guide: Programming Parity Set the type of parity for RS-232C transmission. EVEN MARK SPACE NONE 7-58. LS 3070 Product Reference Guide: Programming Check Parity Select whether or not to check parity for RS-232C transmissions. CHECK PARITY DO NOT CHECK PARITY 7-59.

LS 3070 Product Reference Guide: Programming Hardware Handshaking Select the type of RS-232C hardware handshaking protocol. NONE RTS/CTS 7-60. LS 3070 Product Reference Guide: Programming Software Handshaking Select the type of RS-232C software handshaking protocol. NONE ACK/NAK ACK/NAK with ENQ ENQ ONLY 7-61.

LS 3070 Product Reference Guide: Programming Serial Response Timeout To set a serial (RS-232C) response timeout: 1. Scan the SERIAL RESPONSE TIMEOUT bar code below. Scan two bar codes from the next two pages which represent the desired timeout. You must always scan two bar codes. LS 3070 Product Reference Guide: Programming 7-63. LS 3070 Product Reference Guide: Programming CANCEL 7-64. LS 3070 Product Reference Guide: Programming Stop Bit Select Select the desired number of stop bits for RS-232C communications.

1 STOP BIT 2 STOP BITS 7-65. LS 3070 Product Reference Guide: Programming ASCII Data Format Select either 7-bit or 8-bit ASCII format for RS-232C communications. 7-BIT 8-BIT 7-66. LS 3070 Product Reference Guide: Programming RTS Line State Select the desired option. LINE HIGH LINE LOW 7-67. LS 3070 Product Reference Guide: Programming Intercharacter Delay To set a host communications intercharacter delay: 1. Scan the INTERCHARACTER DELAY bar code below.

Scan two bar codes from the next two pages which represent the desired delay. You must always scan two bar codes. LS 3070 Product Reference Guide: Programming 7-69.

LS 3070 Product Reference Guide: Programming CANCEL 7-70. LS 3070 Product Reference Guide: Programming Transmit Code ID Character Select whether to enable or disable this parameter. TRANSMIT CODE ID CHARACTER DO NOT TRANSMIT CODE ID CHARACTER 7-71. LS 3070 Product Reference Guide: Programming Transmit AIM Code ID Select whether to enable or disable this parameter. This parameter is only valid when Transmit Code ID Character is enabled. TRANSMIT AIM CODE ID DO NOT TRANSMIT AIM CODE ID.

LS 3070 Product Reference Guide: Programming Ignore Unknown Characters Scan the appropriate bar code to enable or disable this parameter. ENABLE DISABLE 7-73.

LS 3070 Product Reference Guide: Programming OCIA Clock Polarity Select whether the OCIA clock pulse polarity will be rising or falling. RISING FALLING 7-74. LS 3070 Product Reference Guide: Programming OCIA Transmit Timeout To set an OCIA Transmit Timeout 1. Scan the OCIA TRANSMIT TIMEOUT bar code below. Scan two bar codes from the next two pages which represent the desired timeout - Between 3 and 30 seconds. You must always scan two bar codes. LS 3070 Product Reference Guide: Programming 7-76.

LS 3070 Product Reference Guide: Programming CANCEL 7-77. LS 3070 Product Reference Guide: Programming NCR 2152 Fast Transmit This selects the data transmission speed of the NCR 2152 POS terminal. Depending on the version of NCR 2152, selecting this option may increase the possibility of lost or mis-transmitted data. LS 3070 Product Reference Guide: Programming IBM 4683 Magstripe Communications Select whether to enable or disable IBM 4683/84 magstripe communications.

ENABLE DISABLE 7-79. LS 3070 Product Reference Guide: Programming International Keypad Emulation Select whether to enable or disable this parameter. Used only with IBM AT/XT/PS2. ENABLE DISABLE 7-80. LS 3070 Product Reference Guide: Programming International Keypad Emulation Fast Transmit Select whether to enable or disable this parameter. Used only with IBM AT/XT/PS2, and with International Keyboard Emulation enabled. ENABLE DISABLE 7-81.

LS 3070 Product Reference Guide: Programming National Keyboard Types Select National Type for the keyboard. English French German French International 7-82. LS 3070 Product Reference Guide: Programming Spanish Italian Swedish U.K. English 7-83. LS 3070 Product Reference Guide: Programming Set Transmission Frequency All Countries Except France To set the initial channel in all countries except France: 1. Scan the SELECT CHANNEL NUMBER bar code below.

Scan two numeric keypad bar codes to set the two-digit channel number, which must be between 02 - 81. LS 3070 Product Reference Guide: Programming 7-85. LS 3070 Product Reference Guide: Programming CANCEL 7-86. LS 3070 Product Reference Guide: Programming Wait for Host Interface Response Time Programming this parameter overrides the automatically set wait for host timeout value. Conversely, programming a value of zero enables the automatic wait for host response timeout calculation feature.

LS 3070 Product Reference Guide: Programming 7-88. LS 3070 Product Reference Guide: Programming CANCEL 7-89. LS 3070 Product Reference Guide: Programming Reserved For Future Use ITEM 1 ENABLE ITEM 1 DISABLE ITEM 2 ENABLE ITEM 2 DISABLE 7-90. LS 3070 Product Reference Guide: Programming ITEM 3 ENABLE ITEM 3 DISABLE ITEM 4 ENABLE ITEM 4 DISABLE 7-91. LS 3070 Product Reference Guide: Programming ITEM 5 ENABLE ITEM 5 DISABLE ITEM 6 ENABLE ITEM 6 DISABLE 7-92. LS 3070 Product Reference Guide: Programming ITEM 7 ENABLE ITEM 7 DISABLE ITEM 8 ENABLE ITEM 8 DISABLE 7-93.

LS 3070 Product Reference Guide: Programming APPLICATIONS VALUE 0 TO 255 ENTER 3-DIGIT NUMBER FROM NEXT 2 PAGES 7-94. LS 3070 Product Reference Guide: Programming 7-95. LS 3070 Product Reference Guide: Programming CANCEL 7-96. LS 3070 Product Reference Guide: Programming Pairing PAIR 7-97. Chapter 8 Keyboard Maps ASCII Table The following values can be assigned as prefixes or suffixes for data transmission. Not all options are available on every keyboard. Refer to your own keyboard or Keyboard Identifier Maps on page 8-5 ASCII Full ASCII Code Value 39 Encode Char.

LS 3070 Product Reference Guide: Keyboard Maps ASCII Full ASCII Code Value 39 Encode Char. 1057 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 1075 1076 1077. LS 3070 Product Reference Guide: Keyboard Maps ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I. LS 3070 Product Reference Guide: Keyboard Maps F Keys Keystroke 5012 F 12 5013 F 13 5014 F 14 5015 F 15 5016 F 16 5017 F 17 5018 F 18 5019 F 19 5020 F 20 5021 F 21.

LS 3070 Product Reference Guide: Keyboard Maps Keyboard Identifier Maps 5001 5002 7014 5003 5004 7009 5005 5006 5007 5008 5009 5010 5001 5002 5003 5004 7009 5005 5006 5007 5008 5009 5010 IBM PC/XT and Clones IBM PC/AT and Clones. LS 3070 Product Reference Guide: Keyboard Maps 4013 4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4001 4002 4003 4004 4005 4006 4007 4008 4009 4010 4011 4012 3003 3004 3005 7009 3006 3007 3008 6059 3010. LS 3070 Product Reference Guide: Keyboard Maps 7014 5001 5002 5003 5004 7009 6059 7004.3001 for IBM 3151 IBM 3151 5001 5002 5003 5004 5005 7009 5005 5006 5007 5008 5009 5010 5011 DEC VT2XX/VT3XX/VT4XX 5011 5006 5007 5008. LS 3070 Product Reference Guide: Keyboard Maps 5101 5102 5103 5104 5105 5001 5002 5003 5004 5005 7009 5101 5102 5103 5104 5105 5001 5002 5003 5004 5005 7009 5106 5107 5108 5109 5110 5111 5006 5007 5008 5009 5010. LS 3070 Product Reference Guide: Keyboard Maps 5101 5102 5013 5104 5105 5106 5001 5002 5003 5004 5005 5006 7009 3030 3023 5001 5002 5003 7001 7019 7009 3032 7002 7014 7010 7013 5111 5113 5107 5108 5109 5110 5112. LS 3070 Product Reference Guide: Keyboard Maps 3040 3041 3030 3031 3050 3051 3042 3043 3033 3032 3052 3053 3044 3045 3034 3035 3054 3055 3046 3047 3036 3037 3056 3057 3001 3025 3026 5001 5002 5003 7001 7019 7009.

LS 3070 Product Reference Guide: Keyboard Maps 3040 3041 3030 3031 3050 3051 3043 3042 3033 3032 3052 3053 3044 3045 3034 3035 3054 3055 3046 3047 3036 3037 3056 3057 3001 7021 7020 7022 SHIFT SHIFT NORMAL NORMAL 3023. LS 3070 Product Reference Guide: Keyboard Maps 5001 5006 5002 5007 5003 5008 5004 5009 5005 5010 5001 5002 5003 5004 5005 5011 5012 NCR 2151 5006 5007 NCR 2152 27-KEY 8-12 5013 5016 5014 5017 5015 5018 5019 7013. LS 3070 Product Reference Guide: Keyboard Maps 5001 5007 5013 5002 5008 5014 5003 5009 5015 5004 5010 5016 5005 5011 5017 5006 5012 5018 5001 5003 5005 5007 5009 5002 5004 5006 5008 5010 3022 3018 7009 5019 5021. LS 3070 Product Reference Guide: Keyboard Maps 5004 5003 5002 5001 5003 5001 5002 5015 5013 5014 5027 5025 5026 5005 5006 NCR 280 5004 5006 5005 5007 5016 5018 5019 5017 5028 5029 5030 5031 NCR 2950 8-14 5007. LS 3070 Product Reference Guide: Keyboard Maps 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 1065 1066 1072 1073 1079 1080 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 1048 5012 1046 (1048 IF DOUBLE KEY).

LS 3070 Product Reference Guide: Keyboard Maps 5001 5002 5006 5008 5003 5007 5009 5004 5010 5022 5005 5011 5001 5002 5006 5008 5003 5007 5009 5004 5010 5022 5005 5011 5012 5023 5013 IBM 3683/3684 35-KEY Calculator Style 5012. LS 3070 Product Reference Guide: Keyboard Maps 5001 5029 5030 5002 5027 5006 5003 5028 5007 5004 5025 5022 5005 5001 5029 5030 5002 5027 5006 5003 5028 5007 5004 5025 5022 5005 5031 5012 5035 5008 5032 5009 5013. LS 3070 Product Reference Guide: Keyboard Maps 5001 5038 5009 5007 5054 5002 5039 5044 5049 5055 5018 5040 5045 5050 5056 5003 5041 5046 5051 5057 5004 5042 5047 5052 5058 5005 5043 5048 5053 5059 5004 5001 5005. Index Accessories.4-5 ASCII table.8-1 Base/charger unit. LS 3070XLR.4-9 Standard LS 3070.4-6 Transmission frequency, setting.

LS 3070 Product Reference Guide: Index Transmission Range.3-4 Unpacking.2-1. We’d like to know what you think about this Manual. Please take a moment to fill out this questionaire and fax this form to: (516) 738-3318, or mail to: Symbol Technologies, Inc. One Symbol Plaza M/S B-4 Holtsville, NY.